      WMHChicken coop composite hot air stove

      Compound heating: using two methods of tube heating: flue gas and hot air. Both methods consume all the heat50%about. This unique heating technology combines the advantages of two heating methods.

      Smoke duct: The length starts from the furnace and runs through the entire chicken coop. Set in the span of the chicken coop1/4—1/3The location. Center height of flueone point fiveMeter, diameterthree hundredMade of zinc sheet.

      Air duct: length from the furnace to the back of the chicken coop5-10Mi, set in the middle of the chicken coop span or slightly towards the other end. The height of the air duct is generally within1.8-2.5Between meters. diameterfour hundredfrontfifteenRice is made of zinc plates. The back is made of canvas. both sidesone hundred and twentyThe downward angle of the air outlet is staggered and dispersed.

      Main technical parameters

      model

      Rated heat generationkj/h

      Hot air volumeM3/h

      Heating areaM2

      Air outlet temperature Celsius

      Overall thermal efficiency%

      Rated coal consumptionKg/h

      Experienced coal consumptionKg/g

      Fan power introduction+Hoodkw

      WMH30

      one million two hundred and fifty-five thousand

      eight thousand

      one thousand and four hundred

      one hundred and fifty

      95%

      forty-two

      twelve

      3+0.75

      WMH40

      one million six hundred and seventy-two thousand

      ten thousand

      one thousand and eight hundred

      one hundred and fifty

      95%

      fifty-eight

      fifteen

      4+0.75

      Note:oneThe rated coal consumption refers to the theoretical amount of coal required to reach the rated heat generation.

      twoThe experience of coal consumption refers to the use of standardized insulation, raising commercial chickens, rice husks for flat farming, and outdoors-15Celsius degrees1-3The chick rearing area has reachedthirty-fivecentigrade. Breeding periodforty-fiveThe hourly average coal consumption of the entire batch of chickens in the day.

       

      WMHDual air self-control energy-saving hot blast stove

      1. The heat and flue gas generated by coal combustion are absorbed and utilized within the limits of air through more scientific and reasonable multi pass heat exchange technology, resulting in120-150The hot air in Celsius provides heat for livestock and poultry, while the temperature of the flue gas is effectively controlled withineightyBelow Celsius degrees.
      2. Because the air is directly heated and sent into the building without water, there is no risk of scale or ice formation, and there is no need to install a separate radiator, so there is no need for secondary heat exchange. And the glass wool insulation layer that comes with our furnace body also minimizes the loss of heat, thereby achieving an overall heat utilization rate90%above.
      3. High temperature heat exchange part inside the road hall-Heat resistant tube, manufactured using our factory's anti erosion technology, capable of long-term durabilityone thousand four hundred and fiftyUse at high temperatures of Celsius without damage.
      4. At the same time. This anti erosion technology also solves the problem of high-temperature corrosion of steel, greatly improving the trouble free operation period of the hot blast stove3-5Year, the overall service life has reachedeightYears or more.

      Main technical parameters


      model

      Rated heat generationkj/h

      Hot air volumeM3/h

      Heating areaM2

      Air outlet temperature Celsius

      Overall thermal efficiency%

      Rated coal consumptionKg/h

      Experienced coal consumptionKg/g

      Fan power introduction+Hoodkw

      WMH10

      four hundred and eighteen thousand

      three thousand and eight hundred

      five hundred

      one hundred and fifty

      90%

      fifteen

      five

      two

      WMH15

      six hundred and twenty-seven thousand

      five thousand and six hundred

      seven hundred and fifty

      one hundred and fifty

      90%

      twenty-two

      nine

      1.5x2+0.55

      WMH20

      eight hundred and thirty-six thousand

      eight thousand

      one thousand

      one hundred and fifty

      90%

      thirty

      twelve

      2.2x2+0.55

      WMH25

      one million and forty-five thousand

      nine thousand

      one thousand and two hundred

      one hundred and fifty

      90%

      thirty-six

      fourteen

      3x2+0.55

      WMH30

      one million two hundred and fifty-five thousand

      ten thousand

      one thousand and four hundred

      one hundred and fifty

      90%

      forty-two

      sixteen

      3x2+0.55


      Note:oneIn addition to the commonly used specifications mentioned above, larger models of hot air stoves can also be produced.

      twoTheWMHThe air volume of the hot air stove is the output air volume of the dual fan hot air stove.

      threeThe rated coal consumption refers to the theoretical amount of coal required to reach the rated heat generation.

      fourThe experience of coal consumption refers to the use of standardized insulation, raising commercial chickens, rice husks for flat farming, and outdoors-15Celsius degrees1-3The chick rearing area has reachedthirty-fivecentigrade. Breeding periodforty-fiveHourly average coal consumption of the entire batch of chickens in the sky

      分享到: