综合欧美日韩一区二区,国产精品欧美一区二区三区,欧美日韩第一区,精品丰满熟女一区二区三区

  • <ul id="q1bev"><td id="q1bev"></td></ul>

    <dfn id="q1bev"><td id="q1bev"></td></dfn>

    • Enquiry Hotline

      15864583687

          Enquiry number: +8615864583687 +8618663615891

      PRODUCT
      24-hour counselling hotline

      +8615864583687 +8618663615891

      • FGM gas box pulse bag filter (click to enter)
      FGM gas box pulse bag filter (click to enter)

      Category:Bag filter

      • 售后QQ: 點(diǎn)擊這里給我發(fā)消息
      • 售后QQ: 點(diǎn)擊這里給我發(fā)消息
      Hotline:+8615864583687
      Details

      The FGM air box pulse bag filter (plenum pulse) is a dust collector introduced from the American company Fuiler. This type of dust collector has advantages over other types of dust collectors, such as insufficient kinetic energy intensity during chamber blowback and simultaneous filtering and cleaning of dust with pulse blowing. Therefore, it increases the adaptability of bag dust collectors, improves dust collection efficiency, and prolongs the service life of filter bags. On the entire cement production line, not only can it be used as a dust collection equipment for crushers, dryers, coal mills, grate coolers, and cement mills, but its high concentration and rate type can also be directly used as a raw material vertical mill outlet concentration (500g/Nm) gas.

      The 0-Spea powder selection machine is used for dust collection of gas with an outlet concentration of 1000g/Nm, and the dust concentration of the collected gas is less than 100g/NM. The filter bag adopts polyester needle punched felt filter material, and the average service life can reach more than two years. At present, the equipment has been widely used, not only quickly selected in cement plants, but also promoted and used in industries such as steel and carbon black.

      The gas box pulse dust collector is divided into several box areas, with 32, 64, 96, 128 bags per box. And there is a lift valve driven by a cylinder on each outlet pipe of the box. When the resistance of the dust collector reaches the pre selected value (usually 1500pa), the dust cleaning controller sends a signal. The lift valve of each compartment begins to close to cut off the filtered airflow. Then the solenoid valve of this box is opened (one per box, pressure not less than 0.5MPa), and compressed air flows into the cleaned filter bag to remove the dust. After this action is completed (approximately 10-15 seconds), the lift valve on the outlet pipe will reopen, allowing the box to resume filtering work and follow the above requirements one by one until all dust is cleared.

        The pneumatic pulse bag dust collector adopts a separate chamber for dust cleaning. During dust cleaning, it is isolated and rotated box by box to avoid the secondary flying problem of the jet pulse bag dust collector. At the same time, the compressed air cleaning effect is ensured. The entire box design utilizes a compartment structure, and the ash hopper can be extended to the inlet main pipe. The incoming dusty flue gas directly enters the enlarged ash hopper to achieve pre dust collection effect, and can remove horizontal straight pipes that are prone to blockage. So, the segmented pulse bag filter can not only handle dust containing gases of general concentration, but also handle dust containing gases with a concentration of up to 1000g/Nm.

      This dust collector uses a full box large pulse valve for back blowing and jet cleaning. When removing the bag, open the top cover and directly remove the filter bag, making maintenance simple and versatile.

        & nbsp; & nbsp; Technical parameters

      FGM32-3

      FGM32-4

      FGM32-5

      FGM32-6

      FGM64-4

      FGM64-5

      FGM64-6

      FGM64-7

      FGM64-8

      Processing air volume(mthree/h

      five thousand and seven hundred

      seven thousand and six hundred

      nine thousand and six hundred

      eleven thousand five hundred and twenty

      fifteen thousand three hundred and sixty

      nineteen thousand and two hundred

      twenty-three thousand and forty

      twenty-six thousand and eight hundred

      thirty thousand and seven hundred

      Filter wind speed(m/min

      1.0-2.0Select different filtered wind speeds based on different dust emission points, as shown in the tableone

      Total filtration area(mtwo

      ninety-three

      one hundred and twenty-four

      one hundred and fifty-five

      one hundred and eighty-six

      two hundred and forty-eight

      three hundred and ten

      three hundred and seventy-two

      four hundred and thirty-four

      four hundred and ninety-six

      Filtration area(mtwo

      sixty-two

      ninety-three

      one hundred and twenty-four

      one hundred and fifty-five

      one hundred and eighty-six

      two hundred and forty-eight

      three hundred and ten

      two hundred and seventy-two

      four hundred and thirty-four

      Number of dust collector rooms (pcs)

      three

      four

      five

      six

      four

      five

      six

      seven

      eight

      Total number of filter bags (pieces)

      ninety-six

      one hundred and twenty-eight

      one hundred and sixty

      one hundred and ninety-two

      two hundred and fifty-six

      three hundred and twenty

      three hundred and eighty-four

      four hundred and forty-eight

      five hundred and twelve

      Dust collector resistance(Pa

      1440-1740

      Imported gas dust concentration(g/m3

       200 

       200 

      Imported gas dust concentration(g/mthree

      zero point one

      Dust collector gas bears negative pressure(Pa

      six thousand

      Compressed air for dust cleaning

      Pressure(Pa

      5-7)×tenfive

      Gas consumption(m3/min

      zero point two

      zero point two one

      zero point three

      zero point three five

      zero point five

      zero point five

      zero point eight

      one

      one

      Pulse valve (with solenoid valve)

      Quantity (piece)

      three

      four

      five

      six

      four

      five

      six

      seven

      eight

      Specifications(mm

      twon

      Lift valve (with cylinder)

      Quantity (piece)

      three

      four

      five

      six

      four

      five

      six

      seven

      eight

      Specifications(mm

      Increase the diameter of the valve plate?460, cylinder diameter?63

      Increase the diameter of the valve plate?500, cylinder diameter?80

      Rigid impeller feeder

      Discharge portthree hundred×300mm,height450mm,speed30.31r/min,Power of deceleration motor1.1kwProduction volume24mthree/h

      screw

      Specifications

      diameter?300Production volume30mthree/h(Filling rate Zeta=0.7

      Conveyor

      Gear motor

      model:XWD2.2-5-1/43,power2.2kw

      Air conveying chute

      If the dust concentration in the imported gas is greater than700g/mthreeThe standard and ash discharge device should use larger sized screw conveyors or air chutes

      Dust cleaning program controller

      The transmission voltage is220v,The controller is supplied by the manufacturer, please refer to the controller manual for detailed information

      Dust cleaning program controller

      Diameter and length Φone hundred and thirty×2450mm,Weight of polyester needle punched felt500g/m2Usage temperatureeighty

      Insulation layer area

      twenty-six point five

      twenty-four

      forty-one

      forty-eight point five

      seventy

      ninety-four

      one hundred and eighteen

      one hundred and forty-two

      one hundred and sixty-two

      Total weight of equipment (approximate value, excluding insulation layer)(kg

      two thousand and four hundred

      three thousand and four hundred

      four thousand and four hundred

      five thousand and four hundred

      six thousand and nine hundred

      eight thousand and three hundred

      nine thousand and seven hundred

      eleven thousand and one hundred

      twelve thousand and five hundred

      External dimensions

      two thousand and fifteen×one thousand nine hundred and eighty
      four thousand seven hundred and fifty

      two thousand and fifteen×two thousand six hundred and forty
      four thousand seven hundred and fifty

      two thousand and fifteen×three thousand and three hundred
      four thousand nine hundred and fifty

      two thousand and fifteen×three thousand nine hundred and sixty
      five thousand one hundred and twenty

      two thousand one hundred and fifteen×five thousand one hundred and twenty
      h:4750

      two thousand one hundred and fifteen×six thousand and four hundred
      h:4950

      two thousand one hundred and fifteen×seven thousand six hundred and eighty
      h:5210

      two thousand one hundred and fifteen×eight thousand nine hundred and sixty
      h:5470

      ten thousand two hundred and forty
      h:5770


      twoThe gas consumption in the table refers to the situation of centralized gas supply in the factory. If a separate air compressor is set up, the gas consumption in the table is multiplied byone point threeCoefficient.

      threeThe gross filtration wind speed for processing air volume in the table is1.2m/minCalculated by time, the dust concentration at the user's dust source point is only less than30g/mthree(mark)In the case where the filtered air velocity is also unknown, the selection should be made directly according to the processing air volume indicated in the table.

      The data of the equipment can be improved at any time according to the actual situation on site, and the interpretation right belongs to our company.

      分享到: